aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--lib/Kconfig.debug7
-rw-r--r--net/sunrpc/debugfs.c14
-rw-r--r--net/sunrpc/fail.h21
3 files changed, 42 insertions, 0 deletions
diff --git a/lib/Kconfig.debug b/lib/Kconfig.debug
index 5ddd575159fb..cd78bb0a7dd9 100644
--- a/lib/Kconfig.debug
+++ b/lib/Kconfig.debug
@@ -1971,6 +1971,13 @@ config FAIL_MMC_REQUEST
and to test how the mmc host driver handles retries from
the block device.
+config FAIL_SUNRPC
+ bool "Fault-injection capability for SunRPC"
+ depends on FAULT_INJECTION_DEBUG_FS && SUNRPC_DEBUG
+ help
+ Provide fault-injection capability for SunRPC and
+ its consumers.
+
config FAULT_INJECTION_STACKTRACE_FILTER
bool "stacktrace filter for fault-injection capabilities"
depends on FAULT_INJECTION_DEBUG_FS && STACKTRACE_SUPPORT
diff --git a/net/sunrpc/debugfs.c b/net/sunrpc/debugfs.c
index 56029e3af6ff..eaeb51f83abd 100644
--- a/net/sunrpc/debugfs.c
+++ b/net/sunrpc/debugfs.c
@@ -8,7 +8,9 @@
#include <linux/debugfs.h>
#include <linux/sunrpc/sched.h>
#include <linux/sunrpc/clnt.h>
+
#include "netns.h"
+#include "fail.h"
static struct dentry *topdir;
static struct dentry *rpc_clnt_dir;
@@ -297,6 +299,13 @@ static const struct file_operations fault_disconnect_fops = {
.release = fault_release,
};
+#if IS_ENABLED(CONFIG_FAIL_SUNRPC)
+struct fail_sunrpc_attr fail_sunrpc = {
+ .attr = FAULT_ATTR_INITIALIZER,
+};
+EXPORT_SYMBOL_GPL(fail_sunrpc);
+#endif
+
void __exit
sunrpc_debugfs_exit(void)
{
@@ -321,4 +330,9 @@ sunrpc_debugfs_init(void)
debugfs_create_file("disconnect", S_IFREG | 0400, rpc_fault_dir, NULL,
&fault_disconnect_fops);
+
+#if IS_ENABLED(CONFIG_FAIL_SUNRPC)
+ fault_create_debugfs_attr("fail_sunrpc", NULL,
+ &fail_sunrpc.attr);
+#endif
}
diff --git a/net/sunrpc/fail.h b/net/sunrpc/fail.h
new file mode 100644
index 000000000000..1d402b0d3453
--- /dev/null
+++ b/net/sunrpc/fail.h
@@ -0,0 +1,21 @@
+/* SPDX-License-Identifier: GPL-2.0 */
+/*
+ * Copyright (C) 2021, Oracle. All rights reserved.
+ */
+
+#ifndef _NET_SUNRPC_FAIL_H_
+#define _NET_SUNRPC_FAIL_H_
+
+#include <linux/fault-inject.h>
+
+#if IS_ENABLED(CONFIG_FAULT_INJECTION)
+
+struct fail_sunrpc_attr {
+ struct fault_attr attr;
+};
+
+extern struct fail_sunrpc_attr fail_sunrpc;
+
+#endif /* CONFIG_FAULT_INJECTION */
+
+#endif /* _NET_SUNRPC_FAIL_H_ */