aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/devicetree')
-rw-r--r--Documentation/devicetree/bindings/firmware/intel,stratix10-svc.txt57
-rw-r--r--Documentation/devicetree/bindings/fpga/intel-stratix10-soc-fpga-mgr.txt17
-rw-r--r--Documentation/devicetree/bindings/misc/pvpanic-mmio.txt29
-rw-r--r--Documentation/devicetree/bindings/nvmem/amlogic-efuse.txt3
4 files changed, 106 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/firmware/intel,stratix10-svc.txt b/Documentation/devicetree/bindings/firmware/intel,stratix10-svc.txt
new file mode 100644
index 000000000000..1fa66065acc6
--- /dev/null
+++ b/Documentation/devicetree/bindings/firmware/intel,stratix10-svc.txt
@@ -0,0 +1,57 @@
+Intel Service Layer Driver for Stratix10 SoC
+============================================
+Intel Stratix10 SoC is composed of a 64 bit quad-core ARM Cortex A53 hard
+processor system (HPS) and Secure Device Manager (SDM). When the FPGA is
+configured from HPS, there needs to be a way for HPS to notify SDM the
+location and size of the configuration data. Then SDM will get the
+configuration data from that location and perform the FPGA configuration.
+
+To meet the whole system security needs and support virtual machine requesting
+communication with SDM, only the secure world of software (EL3, Exception
+Layer 3) can interface with SDM. All software entities running on other
+exception layers must channel through the EL3 software whenever it needs
+service from SDM.
+
+Intel Stratix10 service layer driver, running at privileged exception level
+(EL1, Exception Layer 1), interfaces with the service providers and provides
+the services for FPGA configuration, QSPI, Crypto and warm reset. Service layer
+driver also manages secure monitor call (SMC) to communicate with secure monitor
+code running in EL3.
+
+Required properties:
+-------------------
+The svc node has the following mandatory properties, must be located under
+the firmware node.
+
+- compatible: "intel,stratix10-svc"
+- method: smc or hvc
+ smc - Secure Monitor Call
+ hvc - Hypervisor Call
+- memory-region:
+ phandle to the reserved memory node. See
+ Documentation/devicetree/bindings/reserved-memory/reserved-memory.txt
+ for details
+
+Example:
+-------
+
+ reserved-memory {
+ #address-cells = <2>;
+ #size-cells = <2>;
+ ranges;
+
+ service_reserved: svcbuffer@0 {
+ compatible = "shared-dma-pool";
+ reg = <0x0 0x0 0x0 0x1000000>;
+ alignment = <0x1000>;
+ no-map;
+ };
+ };
+
+ firmware {
+ svc {
+ compatible = "intel,stratix10-svc";
+ method = "smc";
+ memory-region = <&service_reserved>;
+ };
+ };
diff --git a/Documentation/devicetree/bindings/fpga/intel-stratix10-soc-fpga-mgr.txt b/Documentation/devicetree/bindings/fpga/intel-stratix10-soc-fpga-mgr.txt
new file mode 100644
index 000000000000..6e03f79287fb
--- /dev/null
+++ b/Documentation/devicetree/bindings/fpga/intel-stratix10-soc-fpga-mgr.txt
@@ -0,0 +1,17 @@
+Intel Stratix10 SoC FPGA Manager
+
+Required properties:
+The fpga_mgr node has the following mandatory property, must be located under
+firmware/svc node.
+
+- compatible : should contain "intel,stratix10-soc-fpga-mgr"
+
+Example:
+
+ firmware {
+ svc {
+ fpga_mgr: fpga-mgr {
+ compatible = "intel,stratix10-soc-fpga-mgr";
+ };
+ };
+ };
diff --git a/Documentation/devicetree/bindings/misc/pvpanic-mmio.txt b/Documentation/devicetree/bindings/misc/pvpanic-mmio.txt
new file mode 100644
index 000000000000..985e90736780
--- /dev/null
+++ b/Documentation/devicetree/bindings/misc/pvpanic-mmio.txt
@@ -0,0 +1,29 @@
+* QEMU PVPANIC MMIO Configuration bindings
+
+QEMU's emulation / virtualization targets provide the following PVPANIC
+MMIO Configuration interface on the "virt" machine.
+type:
+
+- a read-write, 16-bit wide data register.
+
+QEMU exposes the data register to guests as memory mapped registers.
+
+Required properties:
+
+- compatible: "qemu,pvpanic-mmio".
+- reg: the MMIO region used by the device.
+ * Bytes 0x0 Write panic event to the reg when guest OS panics.
+ * Bytes 0x1 Reserved.
+
+Example:
+
+/ {
+ #size-cells = <0x2>;
+ #address-cells = <0x2>;
+
+ pvpanic-mmio@9060000 {
+ compatible = "qemu,pvpanic-mmio";
+ reg = <0x0 0x9060000 0x0 0x2>;
+ };
+};
+
diff --git a/Documentation/devicetree/bindings/nvmem/amlogic-efuse.txt b/Documentation/devicetree/bindings/nvmem/amlogic-efuse.txt
index e3298e18de26..2e0723ab3384 100644
--- a/Documentation/devicetree/bindings/nvmem/amlogic-efuse.txt
+++ b/Documentation/devicetree/bindings/nvmem/amlogic-efuse.txt
@@ -2,6 +2,8 @@
Required properties:
- compatible: should be "amlogic,meson-gxbb-efuse"
+- clocks: phandle to the efuse peripheral clock provided by the
+ clock controller.
= Data cells =
Are child nodes of eFuse, bindings of which as described in
@@ -11,6 +13,7 @@ Example:
efuse: efuse {
compatible = "amlogic,meson-gxbb-efuse";
+ clocks = <&clkc CLKID_EFUSE>;
#address-cells = <1>;
#size-cells = <1>;