aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/pmbus.rst
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon/pmbus.rst')
-rw-r--r--Documentation/hwmon/pmbus.rst22
1 files changed, 17 insertions, 5 deletions
diff --git a/Documentation/hwmon/pmbus.rst b/Documentation/hwmon/pmbus.rst
index 66b3e894612f..fb3ad67dedc1 100644
--- a/Documentation/hwmon/pmbus.rst
+++ b/Documentation/hwmon/pmbus.rst
@@ -143,10 +143,9 @@ Emerson DS1200 power modules might look as follows::
| PMBUS_HAVE_FAN12 | PMBUS_HAVE_STATUS_FAN12,
};
- static int ds1200_probe(struct i2c_client *client,
- const struct i2c_device_id *id)
+ static int ds1200_probe(struct i2c_client *client)
{
- return pmbus_do_probe(client, id, &ds1200_info);
+ return pmbus_do_probe(client, &ds1200_info);
}
static int ds1200_remove(struct i2c_client *client)
@@ -166,7 +165,7 @@ Emerson DS1200 power modules might look as follows::
.driver = {
.name = "ds1200",
},
- .probe = ds1200_probe,
+ .probe_new = ds1200_probe,
.remove = ds1200_remove,
.id_table = ds1200_id,
};
@@ -211,6 +210,10 @@ inX_lcrit_alarm Voltage critical low alarm.
inX_crit_alarm Voltage critical high alarm.
From VOLTAGE_OV_FAULT status.
inX_label "vin", "vcap", or "voutY"
+inX_rated_min Minimum rated voltage.
+ From MFR_VIN_MIN or MFR_VOUT_MIN register.
+inX_rated_max Maximum rated voltage.
+ From MFR_VIN_MAX or MFR_VOUT_MAX register.
currX_input Measured current. From READ_IIN or READ_IOUT register.
currX_max Maximum current.
@@ -230,6 +233,8 @@ currX_crit_alarm Current critical high alarm.
currX_label "iin", "iinY", "iinY.Z", "ioutY", or "ioutY.Z",
where Y reflects the page number and Z reflects the
phase.
+currX_rated_max Maximum rated current.
+ From MFR_IIN_MAX or MFR_IOUT_MAX register.
powerX_input Measured power. From READ_PIN or READ_POUT register.
powerX_cap Output power cap. From POUT_MAX register.
@@ -244,10 +249,12 @@ powerX_crit_alarm Output power critical high alarm.
powerX_label "pin", "pinY", "pinY.Z", "poutY", or "poutY.Z",
where Y reflects the page number and Z reflects the
phase.
+powerX_rated_max Maximum rated power.
+ From MFR_PIN_MAX or MFR_POUT_MAX register.
tempX_input Measured temperature.
From READ_TEMPERATURE_X register.
-tempX_min Mimimum temperature. From UT_WARN_LIMIT register.
+tempX_min Minimum temperature. From UT_WARN_LIMIT register.
tempX_max Maximum temperature. From OT_WARN_LIMIT register.
tempX_lcrit Critical low temperature.
From UT_FAULT_LIMIT register.
@@ -265,4 +272,9 @@ tempX_lcrit_alarm Chip temperature critical low alarm. Set by comparing
tempX_crit_alarm Chip temperature critical high alarm. Set by comparing
READ_TEMPERATURE_X with OT_FAULT_LIMIT if
TEMP_OT_FAULT status is set.
+tempX_rated_min Minimum rated temperature.
+ From MFR_TAMBIENT_MIN register.
+tempX_rated_max Maximum rated temperature.
+ From MFR_TAMBIENT_MAX, MFR_MAX_TEMP_1, MFR_MAX_TEMP_2 or
+ MFR_MAX_TEMP_3 register.
======================= ========================================================