authorChangSyun Peng <allenpeng@synology.com>2020-07-31 17:50:31 +0800
committerSong Liu <songliubraving@fb.com>2020-08-02 23:54:31 -0700
commit45a4d8fd6c7926e7991a1b29233d725fe12935da (patch)
tree412d26f3b5d9f5958a3678c77b07a7efc96ca619 /drivers/md
parentmd/raid5: Fix Force reconstruct-write io stuck in degraded raid5 (diff)
downloadwireguard-linux-45a4d8fd6c7926e7991a1b29233d725fe12935da.tar.xz
wireguard-linux-45a4d8fd6c7926e7991a1b29233d725fe12935da.zip
md/raid5: Allow degraded raid6 to do rmw
Degraded raid6 always do reconstruct-write now. With raid6 xor supported, we can do rmw in degraded raid6. This patch can reduce many read IOs to improve performance. If the failed disk is P, Q or the disk we want to write to, we may need to do reconstruct-write in max degraded raid6. In this situation we can not read enough data from handle_stripe_dirtying() so we have to set force_rcw in handle_stripe_fill() to read all data. Reviewed-by: Alex Wu <alexwu@synology.com> Reviewed-by: BingJing Chang <bingjingc@synology.com> Reviewed-by: Danny Shih <dannyshih@synology.com> Signed-off-by: ChangSyun Peng <allenpeng@synology.com> Signed-off-by: Song Liu <songliubraving@fb.com>
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/raid5.c22
1 files changed, 16 insertions, 6 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c
index 9aab66fd1003..657634a7e8d1 100644
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -3557,6 +3557,7 @@ static int need_this_block(struct stripe_head *sh, struct stripe_head_state *s,
struct r5dev *fdev[2] = { &sh->dev[s->failed_num[0]],
&sh->dev[s->failed_num[1]] };
int i;
+ bool force_rcw = (sh->raid_conf->rmw_level == PARITY_DISABLE_RMW);
if (test_bit(R5_LOCKED, &dev->flags) ||
@@ -3615,18 +3616,27 @@ static int need_this_block(struct stripe_head *sh, struct stripe_head_state *s,
* devices must be read.
*/
return 1;
+
+ if (s->failed >= 2 &&
+ (fdev[i]->towrite ||
+ s->failed_num[i] == sh->pd_idx ||
+ s->failed_num[i] == sh->qd_idx) &&
+ !test_bit(R5_UPTODATE, &fdev[i]->flags))
+ /* In max degraded raid6, If the failed disk is P, Q,
+ * or we want to read the failed disk, we need to do
+ * reconstruct-write.
+ */
+ force_rcw = true;
}
- /* If we are forced to do a reconstruct-write, either because
- * the current RAID6 implementation only supports that, or
- * because parity cannot be trusted and we are currently
- * recovering it, there is extra need to be careful.
+ /* If we are forced to do a reconstruct-write, because parity
+ * cannot be trusted and we are currently recovering it, there
+ * is extra need to be careful.
* If one of the devices that we would need to read, because
* it is not being overwritten (and maybe not written at all)
* is missing/faulty, then we need to read everything we can.
*/
- if (sh->raid_conf->level != 6 &&
- sh->raid_conf->rmw_level != PARITY_DISABLE_RMW &&
+ if (!force_rcw &&
sh->sector < sh->raid_conf->mddev->recovery_cp)
/* reconstruct-write isn't being forced */
return 0;