aboutsummaryrefslogtreecommitdiffstatshomepage
path: root/scripts/Makefile.thinlto
diff options
context:
space:
mode:
authorGuenter Roeck <linux@roeck-us.net>2026-10-30 20:02:08 -0700
committerGuenter Roeck <linux@roeck-us.net>2026-11-02 07:00:05 -0800
commit7cd60538073e465310c94b2a2f0ea8d2f03768ef (patch)
treee5a1c98a4465fa19bb856df0aca631d2c9094dad /scripts/Makefile.thinlto
parenthwmon: (lm75) Fix setting polarity mask for chips with 16-bit config register (diff)
hwmon: (tmp108) Fix initial conversion delay and wait until ready
In tmp108_common_probe(), the driver only adds the 30 ms conversion delay (TMP108_CONVERSION_TIME_MS) to ready_time if the sensor was previously in TMP108_MODE_SHUTDOWN. However, the TMP108 hardware defaults to continuous conversion mode (TMP108_MODE_CONTINUOUS) upon power-on reset, including immediately after enabling the vcc supply regulator during probe, while the temperature register retains its power-on reset value of 0x0000 (0°C) until the first conversion completes. Because the initial mode is not shutdown, the delay is bypassed and early reads via thermal zone registration or sysfs before the first conversion finishes return an uninitialized 0°C reading. In addition, returning -EAGAIN from tmp108_read() while waiting for a conversion to complete after probe or resume can trigger an unnecessary tight retry loop in callers or fail initial reads. Unconditionally set ready_time to TMP108_CONVERSION_TIME_MS ahead in tmp108_common_probe(), track ready_time as ktime_t, and wait for the remaining conversion time in tmp108_read() using usleep_range() instead of returning -EAGAIN. Reported-by: Sashiko <sashiko-bot@kernel.org> Fixes: 66e1c9171339 ("hwmon: Add Texas Instruments TMP108 temperature sensor driver.") Cc: stable@vger.kernel.org Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'scripts/Makefile.thinlto')
0 files changed, 0 insertions, 0 deletions