aboutsummaryrefslogtreecommitdiffstatshomepage
path: root/tools/perf/scripts/python/export-to-postgresql.py
diff options
context:
space:
mode:
authorAndre Przywara <andre.przywara@arm.com>2020-08-28 14:06:00 +0100
committerFlorian Fainelli <f.fainelli@gmail.com>2020-09-10 13:35:19 -0700
commit9d6693369fc782b33168255fe3cd760796dba59c (patch)
tree699b3477fda29919d799aa2edf03929b71ad1421 /tools/perf/scripts/python/export-to-postgresql.py
parentARM: dts: NSP: replace status value "ok" by "okay" (diff)
downloadwireguard-linux-9d6693369fc782b33168255fe3cd760796dba59c.tar.xz
wireguard-linux-9d6693369fc782b33168255fe3cd760796dba59c.zip
ARM: dts: Cygnus: Fix SP805 clocks
The SP805 DT binding requires two clocks to be specified, but the Broadcom Cygnus DT currently only specifies one clock. In practice, Linux would pick a clock named "apb_pclk" for the bus clock, and the Linux and U-Boot SP805 driver would use the first clock to derive the actual watchdog counter frequency. Since currently both are the very same clock, we can just double the clock reference, and add the correct clock-names, to match the binding. Signed-off-by: Andre Przywara <andre.przywara@arm.com> Reviewed-by: Ray Jui <ray.jui@broadcom.com> Acked-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Diffstat (limited to 'tools/perf/scripts/python/export-to-postgresql.py')
0 files changed, 0 insertions, 0 deletions