aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/ABI
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-counter230
-rw-r--r--Documentation/ABI/testing/sysfs-bus-counter-104-quad-836
-rw-r--r--Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec16
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio8
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-816
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad593335
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-sps302
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-temperature-max3185624
8 files changed, 366 insertions, 1 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-counter b/Documentation/ABI/testing/sysfs-bus-counter
new file mode 100644
index 000000000000..566bd99fe0a5
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-counter
@@ -0,0 +1,230 @@
+What: /sys/bus/counter/devices/counterX/countY/count
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Count data of Count Y represented as a string.
+
+What: /sys/bus/counter/devices/counterX/countY/ceiling
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Count value ceiling for Count Y. This is the upper limit for the
+ respective counter.
+
+What: /sys/bus/counter/devices/counterX/countY/floor
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Count value floor for Count Y. This is the lower limit for the
+ respective counter.
+
+What: /sys/bus/counter/devices/counterX/countY/count_mode
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Count mode for channel Y. The ceiling and floor values for
+ Count Y are used by the count mode where required. The following
+ count modes are available:
+
+ normal:
+ Counting is continuous in either direction.
+
+ range limit:
+ An upper or lower limit is set, mimicking limit switches
+ in the mechanical counterpart. The upper limit is set to
+ the Count Y ceiling value, while the lower limit is set
+ to the Count Y floor value. The counter freezes at
+ count = ceiling when counting up, and at count = floor
+ when counting down. At either of these limits, the
+ counting is resumed only when the count direction is
+ reversed.
+
+ non-recycle:
+ The counter is disabled whenever a counter overflow or
+ underflow takes place. The counter is re-enabled when a
+ new count value is loaded to the counter via a preset
+ operation or direct write.
+
+ modulo-n:
+ A count value boundary is set between the Count Y floor
+ value and the Count Y ceiling value. The counter is
+ reset to the Count Y floor value at count = ceiling when
+ counting up, while the counter is set to the Count Y
+ ceiling value at count = floor when counting down; the
+ counter does not freeze at the boundary points, but
+ counts continuously throughout.
+
+What: /sys/bus/counter/devices/counterX/countY/count_mode_available
+What: /sys/bus/counter/devices/counterX/countY/error_noise_available
+What: /sys/bus/counter/devices/counterX/countY/function_available
+What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Discrete set of available values for the respective Count Y
+ configuration are listed in this file. Values are delimited by
+ newline characters.
+
+What: /sys/bus/counter/devices/counterX/countY/direction
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates the count direction of Count
+ Y. Two count directions are available: forward and backward.
+
+ Some counter devices are able to determine the direction of
+ their counting. For example, quadrature encoding counters can
+ determine the direction of movement by evaluating the leading
+ phase of the respective A and B quadrature encoding signals.
+ This attribute exposes such count directions.
+
+What: /sys/bus/counter/devices/counterX/countY/enable
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Whether channel Y counter is enabled. Valid attribute values are
+ boolean.
+
+ This attribute is intended to serve as a pause/unpause mechanism
+ for Count Y. Suppose a counter device is used to count the total
+ movement of a conveyor belt: this attribute allows an operator
+ to temporarily pause the counter, service the conveyor belt,
+ and then finally unpause the counter to continue where it had
+ left off.
+
+What: /sys/bus/counter/devices/counterX/countY/error_noise
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates whether excessive noise is
+ present at the channel Y counter inputs.
+
+What: /sys/bus/counter/devices/counterX/countY/function
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Count function mode of Count Y; count function evaluation is
+ triggered by conditions specified by the Count Y signalZ_action
+ attributes. The following count functions are available:
+
+ increase:
+ Accumulated count is incremented.
+
+ decrease:
+ Accumulated count is decremented.
+
+ pulse-direction:
+ Rising edges on signal A updates the respective count.
+ The input level of signal B determines direction.
+
+ quadrature x1 a:
+ If direction is forward, rising edges on quadrature pair
+ signal A updates the respective count; if the direction
+ is backward, falling edges on quadrature pair signal A
+ updates the respective count. Quadrature encoding
+ determines the direction.
+
+ quadrature x1 b:
+ If direction is forward, rising edges on quadrature pair
+ signal B updates the respective count; if the direction
+ is backward, falling edges on quadrature pair signal B
+ updates the respective count. Quadrature encoding
+ determines the direction.
+
+ quadrature x2 a:
+ Any state transition on quadrature pair signal A updates
+ the respective count. Quadrature encoding determines the
+ direction.
+
+ quadrature x2 b:
+ Any state transition on quadrature pair signal B updates
+ the respective count. Quadrature encoding determines the
+ direction.
+
+ quadrature x4:
+ Any state transition on either quadrature pair signals
+ updates the respective count. Quadrature encoding
+ determines the direction.
+
+What: /sys/bus/counter/devices/counterX/countY/name
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates the device-specific name of
+ Count Y. If possible, this should match the name of the
+ respective channel as it appears in the device datasheet.
+
+What: /sys/bus/counter/devices/counterX/countY/preset
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ If the counter device supports preset registers -- registers
+ used to load counter channels to a set count upon device-defined
+ preset operation trigger events -- the preset count for channel
+ Y is provided by this attribute.
+
+What: /sys/bus/counter/devices/counterX/countY/preset_enable
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Whether channel Y counter preset operation is enabled. Valid
+ attribute values are boolean.
+
+What: /sys/bus/counter/devices/counterX/countY/signalZ_action
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Action mode of Count Y for Signal Z. This attribute indicates
+ the condition of Signal Z that triggers the count function
+ evaluation for Count Y. The following action modes are
+ available:
+
+ none:
+ Signal does not trigger the count function. In
+ Pulse-Direction count function mode, this Signal is
+ evaluated as Direction.
+
+ rising edge:
+ Low state transitions to high state.
+
+ falling edge:
+ High state transitions to low state.
+
+ both edges:
+ Any state transition.
+
+What: /sys/bus/counter/devices/counterX/name
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates the device-specific name of
+ the Counter. This should match the name of the device as it
+ appears in its respective datasheet.
+
+What: /sys/bus/counter/devices/counterX/num_counts
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates the total number of Counts
+ belonging to the Counter.
+
+What: /sys/bus/counter/devices/counterX/num_signals
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates the total number of Signals
+ belonging to the Counter.
+
+What: /sys/bus/counter/devices/counterX/signalY/signal
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Signal data of Signal Y represented as a string.
+
+What: /sys/bus/counter/devices/counterX/signalY/name
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Read-only attribute that indicates the device-specific name of
+ Signal Y. If possible, this should match the name of the
+ respective signal as it appears in the device datasheet.
diff --git a/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8
new file mode 100644
index 000000000000..46b1f33b2fce
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8
@@ -0,0 +1,36 @@
+What: /sys/bus/counter/devices/counterX/signalY/index_polarity
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Active level of index input Signal Y; irrelevant in
+ non-synchronous load mode.
+
+What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
+What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Discrete set of available values for the respective Signal Y
+ configuration are listed in this file.
+
+What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Configure the counter associated with Signal Y for
+ non-synchronous or synchronous load mode. Synchronous load mode
+ cannot be selected in non-quadrature (Pulse-Direction) clock
+ mode.
+
+ non-synchronous:
+ A logic low level is the active level at this index
+ input. The index function (as enabled via preset_enable)
+ is performed directly on the active level of the index
+ input.
+
+ synchronous:
+ Intended for interfacing with encoder Index output in
+ quadrature clock mode. The active level is configured
+ via index_polarity. The index function (as enabled via
+ preset_enable) is performed synchronously with the
+ quadrature clock on the active level of the index input.
diff --git a/Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec b/Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec
new file mode 100644
index 000000000000..7d2e7b363467
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec
@@ -0,0 +1,16 @@
+What: /sys/bus/counter/devices/counterX/countY/prescaler_available
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Discrete set of available values for the respective Count Y
+ configuration are listed in this file. Values are delimited by
+ newline characters.
+
+What: /sys/bus/counter/devices/counterX/countY/prescaler
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Configure the prescaler value associated with Count Y.
+ On the FlexTimer, the counter clock source passes through a
+ prescaler (i.e. a counter). This acts like a clock
+ divider.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index 864f8efd12e5..6aef7dbbde44 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -1656,6 +1656,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_raw
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Raw counter device counts from channel Y. For quadrature
counters, multiplication by an available [Y]_scale results in
the counts of a single quadrature signal phase from channel Y.
@@ -1664,6 +1666,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_raw
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Raw counter device index value from channel Y. This attribute
provides an absolute positional reference (e.g. a pulse once per
revolution) which may be used to home positional systems as
@@ -1673,6 +1677,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_count_count_direction_available
KernelVersion: 4.12
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
A list of possible counting directions which are:
- "up" : counter device is increasing.
- "down": counter device is decreasing.
@@ -1681,6 +1687,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_direction
KernelVersion: 4.12
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Raw counter device counters direction for channel Y.
What: /sys/bus/iio/devices/iio:deviceX/in_phaseY_raw
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8
index 7fac2c268d9a..bac3d0d48b7b 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8
+++ b/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8
@@ -6,6 +6,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_index_synchronous_mode_available
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Discrete set of available values for the respective counter
configuration are listed in this file.
@@ -13,6 +15,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_mode
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Count mode for channel Y. Four count modes are available:
normal, range limit, non-recycle, and modulo-n. The preset value
for channel Y is used by the count mode where required.
@@ -47,6 +51,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_noise_error
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Read-only attribute that indicates whether excessive noise is
present at the channel Y count inputs in quadrature clock mode;
irrelevant in non-quadrature clock mode.
@@ -55,6 +61,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_preset
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
If the counter device supports preset registers, the preset
count for channel Y is provided by this attribute.
@@ -62,6 +70,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_quadrature_mode
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Configure channel Y counter for non-quadrature or quadrature
clock mode. Selecting non-quadrature clock mode will disable
synchronous load mode. In quadrature clock mode, the channel Y
@@ -83,6 +93,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_set_to_preset_on_index
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Whether to set channel Y counter with channel Y preset value
when channel Y index input is active, or continuously count.
Valid attribute values are boolean.
@@ -91,6 +103,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_index_polarity
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Active level of channel Y index input; irrelevant in
non-synchronous load mode.
@@ -98,6 +112,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_synchronous_mode
KernelVersion: 4.10
Contact: linux-iio@vger.kernel.org
Description:
+ This interface is deprecated; please use the Counter subsystem.
+
Configure channel Y counter for non-synchronous or synchronous
load mode. Synchronous load mode cannot be selected in
non-quadrature clock mode.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad5933 b/Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad5933
new file mode 100644
index 000000000000..0e86747c67f8
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad5933
@@ -0,0 +1,35 @@
+What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_frequency_start
+Date: March 2019
+KernelVersion: 3.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ Frequency sweep start frequency in Hz.
+
+What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_frequency_increment
+Date: March 2019
+KernelVersion: 3.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ Frequency increment in Hz (step size) between consecutive
+ frequency points along the sweep.
+
+What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_frequency_points
+Date: March 2019
+KernelVersion: 3.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ Number of frequency points (steps) in the frequency sweep.
+ This value, in conjunction with the
+ out_altvoltageY_frequency_start and the
+ out_altvoltageY_frequency_increment, determines the frequency
+ sweep range for the sweep operation.
+
+What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_settling_cycles
+Date: March 2019
+KernelVersion: 3.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ Number of output excitation cycles (settling time cycles)
+ that are allowed to pass through the unknown impedance,
+ after each frequency increment, and before the ADC is triggered
+ to perform a conversion sequence of the response signal.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-sps30 b/Documentation/ABI/testing/sysfs-bus-iio-sps30
index 143df8e89d08..06e1c272537b 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-sps30
+++ b/Documentation/ABI/testing/sysfs-bus-iio-sps30
@@ -1,6 +1,6 @@
What: /sys/bus/iio/devices/iio:deviceX/start_cleaning
Date: December 2018
-KernelVersion: 4.22
+KernelVersion: 5.0
Contact: linux-iio@vger.kernel.org
Description:
Writing 1 starts sensor self cleaning. Internal fan accelerates
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
new file mode 100644
index 000000000000..3b3509a3ef2f
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
@@ -0,0 +1,24 @@
+What: /sys/bus/iio/devices/iio:deviceX/fault_oc
+KernelVersion: 5.1
+Contact: linux-iio@vger.kernel.org
+Description:
+ Open-circuit fault. The detection of open-circuit faults,
+ such as those caused by broken thermocouple wires.
+ Reading returns either '1' or '0'.
+ '1' = An open circuit such as broken thermocouple wires
+ has been detected.
+ '0' = No open circuit or broken thermocouple wires are detected
+
+What: /sys/bus/iio/devices/iio:deviceX/fault_ovuv
+KernelVersion: 5.1
+Contact: linux-iio@vger.kernel.org
+Description:
+ Overvoltage or Undervoltage Input Fault. The internal circuitry
+ is protected from excessive voltages applied to the thermocouple
+ cables by integrated MOSFETs at the T+ and T- inputs, and the
+ BIAS output. These MOSFETs turn off when the input voltage is
+ negative or greater than VDD.
+ Reading returns either '1' or '0'.
+ '1' = The input voltage is negative or greater than VDD.
+ '0' = The input voltage is positive and less than VDD (normal
+ state).